NVX-360 Configuration
At first-boot the password needs to be set to the default AV username and password. Firmware should be upgraded to the current production firmware - All NVX devices in the project are to run the same version. DTS suggest the use of NVX tool to undertake the upgrade of firmware.
XIO
Curtin University no longer requires devices to be imported into XIO Cloud.
Configuration
This guide is not an exhaustive list, but covers key aspects.
-
Set the following "System Setup" items:
- Hostname - as per grid manager
- DHCP Enabled to On.
-
Set the following "Stream" items for Receivers
- Set the device name based on host name
- If USB is connected, set the USB mode to Remote and enable multi-device pairing
- On any receiver that needs to re-embed audio in the HDMI (typically cap-cam and avb-cam)
- Set DM NAX (AES67) Recieve Mode to Manual and enter the multicast address of the respective stream (Capture or Conference)
- In the routing tab, set the Input Routing Audio Source to DM NAX (AES67) Audio
- Set DM NAX (AES67) Recieve Mode to Manual and enter the multicast address of the respective stream (Capture or Conference)
- On any receiver being used for primary or secondary audio streams (typically fpd1 or prj)
- set the session name to the host name
- enter the provided multicast address
- set the port to 5004
-
Set the following "Stream" items for Transmitters
- Pixel Perfect Processing
- Set the Video multicast address
- Set the device name based on host name
- Set the stream name in both the stream and NAX tabs to the host name
- If USB is connected, set the USB mode to Local and enable multi-device pairing.
- Set the Bitrate type to Variable
-
ENSURE HDCP IS OFF ON INPUTS AND OUTPUTS
-
Note that for the ilecture light, the cam1 and cap-cam require manual configuration and creation of the USB route.
- cap-cam should be set to local mode
- cam1 should be set to remote
- both should be manually paired using eachothers mac address