Skip to main content

NVX-360 Configuration

At first-boot the password needs to be set to the default AV username and password. Firmware should be upgraded to the current production firmware - All NVX devices in the project are to run the same version. DTS suggest the use of NVX tool to undertake the upgrade of firmware.

XIO​

Curtin University no longer requires devices to be imported into XIO Cloud.

Configuration​

This guide is not an exhaustive list, but covers key aspects.

  • Set the following "System Setup" items:

    • Hostname - as per grid manager
    • DHCP Enabled to On.
  • Set the following "Stream" items for Receivers

    • Set the device name based on host name
    • If USB is connected, set the USB mode to Remote and enable multi-device pairing
    • On any receiver that needs to re-embed audio in the HDMI (typically cap-cam and avb-cam)
      • Set DM NAX (AES67) Recieve Mode to Manual and enter the multicast address of the respective stream (Capture or Conference)
        • In the routing tab, set the Input Routing Audio Source to DM NAX (AES67) Audio
    • On any receiver being used for primary or secondary audio streams (typically fpd1 or prj)
      • set the session name to the host name
      • enter the provided multicast address
      • set the port to 5004
  • Set the following "Stream" items for Transmitters

    • Pixel Perfect Processing
    • Set the Video multicast address
    • Set the device name based on host name
    • Set the stream name in both the stream and NAX tabs to the host name
    • If USB is connected, set the USB mode to Local and enable multi-device pairing.
    • Set the Bitrate type to Variable
  • ENSURE HDCP IS OFF ON INPUTS AND OUTPUTS

  • Note that for the ilecture light, the cam1 and cap-cam require manual configuration and creation of the USB route.

    • cap-cam should be set to local mode
    • cam1 should be set to remote
    • both should be manually paired using eachothers mac address